ABB IRB 1200 Product Manual page 759

Hide thumbs Also See for IRB 1200:
Table of Contents

Advertisement

Required tools and equipment
Equipment, etc.
24 VDC power supply
Calibration toolkit, manual
calibration
Standard toolkit
i
Required consumables
Consumable
Cleaning agent
Locking liquid
Sealant
Deciding calibration routine
Decide which calibration routine to be used, based on the information in the table.
Depending on which routine is chosen, action might be required prior to beginning
the repair work of the robot, see the table.
1
Product manual - IRB 1200
3HAC046983-001 Revision: S
The robot is calibrated by either manual calibration or Axis Calibration at factory. Always use the
same calibration method as used at the factory.
Information about valid calibration method is found on the calibration label or in the calibration
menu on the FlexPendant.
If no data is found related to standard calibration, manual calibration is used as default.
Action
Decide which calibration routine to use for
calibrating the robot.
Reference calibration. External cable
packages (DressPack) and tools can
stay fitted on the robot.
Fine calibration. All external cable
packages (DressPack) and tools
must be removed from the robot.
If the robot is to be calibrated with refer-
ence calibration:
Find previous reference values for the axis
or create new reference values. These val-
ues are to be used after the repair proced-
ure is completed, for calibration of the ro-
bot.
If no previous reference values exist, and
no new reference values can be created,
then reference calibration is not possible.
© Copyright 2014 - 2021 ABB. All rights reserved.
4.6.7 Replacing the axis-5 motor with pulley
Article number
Note
-
Used to release the motor brakes.
3HAC051256-001
Includes calibration tools, pins and at-
tachment screws for manual calibration
method.
-
Content is defined in section
toolkit on page
Art. no.
-
3HAB7116-1
3HAC073510-001
Note
Calibrating axis 6 always requires tools to
be removed from the mounting flange (also
for reference calibration) since the mount-
ing flange is used for installation of the
calibration tool.
Follow the instructions given in the refer-
ence calibration routine on the FlexPendant
to create reference values.
Creating new values requires possibility to
move the robot.
Read more about reference calibration for
Axis Calibration in
routine on page
4 Repair
Continued
i
Standard
890.
Note
Isopropanol
Loctite 243
For robots with protection class
IP67
For robots with protection type
Foundry Plus
Trans Clear
For robots with protection type
Hygienic
Note
Reference calibration
819.
Continues on next page
759

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Irb 1200-5/0.9Irb 1200-7/0.7