ABB IRB 1200 Product Manual page 863

Hide thumbs Also See for IRB 1200:
Table of Contents

Advertisement

6
Checking and finalizing the calibration
1
2
3
4
5
After calibration
1
Product manual - IRB 1200
3HAC046983-001 Revision: S
5.6.7 Manual calibration method - calibrating axis 5 and axis 6
Action
Tap Calibrate.
A dialog box is displayed, warning that calibration
of the selected axes will be changed, which cannot
be undone:
Tap Calibrate to proceed.
Tap Cancel to cancel.
Tapping Calibrate results in briefly displaying a
dialog box, announcing that the calibration pro-
cess has started.
The axis is calibrated and the system returns to
the list of available mechanical units.
Action
Release the brakes and manually rotate the axis
to apart the calibration pins from each other. This
is done to avoid damage on the pins if incorrect
operation should occur during next step of jog-
ging.
Jog axis 5 and 6 to zero degree using the Flex-
Pendant.
Check that the synchronization marks on axis 5
and axis 6 are aligned with eachother.
Are they aligned within the tolerances?
If yes, the calibration is verified OK.
If no, redo the fine calibration procedure.
Remove the calibration block from the tubular.
Remove the calibration tool of axes 5 and 6 from
the disk.
Action
Write down the new system parameters on a new
label and stick on top of the calibration label on
the robot.
© Copyright 2014 - 2021 ABB. All rights reserved.
5 Calibration
Continued
Note
Note
xx1400001096
xx1400001097
Note
863

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Irb 1200-5/0.9Irb 1200-7/0.7

Table of Contents