4 Repair
4.3.2 Replacing the axis-4 FPC unit, housing extender unit and housing extender sealings
Continued
4
5
6
7
Continues on next page
270
Action
Refit the screw M6x35 (1 pc). Do not tighten yet.
Refit the rest of the screws (M5x35 (7 pcs)).
Tighten all screws.
Put the cables through the plate hole and refit the
plate.
© Copyright 2014 - 2021 ABB. All rights reserved.
Note
Screw: 3HAB3409-238 (M6x35 (1
pc)).
xx1400000002
Note
Only use specified screws, never
replace them with other screws.
Screw: 3HAB3409-237 (M5x35 (7
pcs)).
xx1400000003
Note
Only use specified screws, never
replace them with other screws.
Tightening torque: 8 Nm.