ABB IRB 1200 Product Manual page 400

Hide thumbs Also See for IRB 1200:
Table of Contents

Advertisement

4 Repair
4.4.3 Replacing the tubular spare parts
Continued
6
Refitting the tubular
Use these procedures to refit the tubular.
Checking the sealing set on tool flange of Hygienic robots
1
2
3
Continues on next page
400
Action
Remove the tilt unit.
Action
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
Check the gasket (A), seal ring unit (B) and
stainless shaft (C) on the tool flange.
Replace if damaged, as described below.
If undamaged and properly seated, skip to the
next procedure table.
Remove the screws and washers.
© Copyright 2014 - 2021 ABB. All rights reserved.
Note
xx1300002470
Note
xx2100001448
xx2100001449
Product manual - IRB 1200
3HAC046983-001 Revision: S

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Irb 1200-5/0.9Irb 1200-7/0.7

Table of Contents