3HAC046983-001 Revision: S
3.4.2 Replacing the sealing set on tool flange of Hygienic robots
Action
Replace the parts with new ones.
Apply a little grease to the screw thread.
Put the gasket in place and then screw the seal
ring unit.
Place the flange tightening tool together with a
3/8" (10 mm) socket spanner on the seal ring unit
and tighten the unit.
© Copyright 2014 - 2021 ABB. All rights reserved.
3 Maintenance
Continued
Note
Grease: Molykote P1900
xx2100001454
xx2100001453
xx2100001455
Flange tightening tool:
3HAC079686-001
Tightening torque: 8 Nm
xx2100001456
Continues on next page