Action
Place the motor at its mounting position
and fasten the attachment screws and
washers just enough to still be able to
move the motor.
Position the robot with the connectors dir-
ected as shown in the figure.
Verify that the top surface of the axis-4
motor is parallel with the mounting flange
surface on the housing, shown in the figure,
when moving the motor.
Install the timing belt to the pulleys and
verify that the belt runs correctly in the
grooves of the pulleys.
© Copyright 2014 - 2021 ABB. All rights reserved.
4.6.6 Replacing the axis-4 timing belt
Note
Screws: 3HAB3409-14 (M5x16).
xx1300002524
Note
Only use specified screws, never replace
them with other screws.
xx1300002612
xx1300002525
Continues on next page