ABB IRB 1200 Product Manual page 260

Hide thumbs Also See for IRB 1200:
Table of Contents

Advertisement

4 Repair
4.3.2 Replacing the axis-4 FPC unit, housing extender unit and housing extender sealings
Continued
6
7
8
9
10
11
Refitting the axis-4 FPC unit
1
Continues on next page
260
Action
Fit the circular part of the radial sealing
assembly tool against the radial sealing.
Fit the tool plate to the other side of the
housing extender unit with the six screws
M6X50.
Screw the screws, little by little, to press
the sealing into place.
Remove the assembly tool.
Check that the sealing is undamaged and
properly fitted.
Refit both the axis-4 mechanical stop and
the axis-4 FPC unit to the housing extender
unit.
Action
For robots with protection type Clean
Room
For robots with food grade lubrication
For robots with protection type Hygienic
Clean the joints that have been opened and
wipe the parts free from particles with
spirit on a lint free.
© Copyright 2014 - 2021 ABB. All rights reserved.
Note
Axis-4 sealing assembly tool set:
3HAC049699-001
xx1400000436
xx1400000437
Note
Product manual - IRB 1200
3HAC046983-001 Revision: S

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Irb 1200-5/0.9Irb 1200-7/0.7

Table of Contents