ABB IRB 1200 Product Manual page 831

Hide thumbs Also See for IRB 1200:
Table of Contents

Advertisement

2
3
Product manual - IRB 1200
3HAC046983-001 Revision: S
5.4.4 Axis Calibration - Running the calibration procedure
Action
Reinstall the protective plugs in both bushings on
each axis, directly after the axis is calibrated.
Replace the plug with new spare part, if missing
or damaged.
Note
For robots with protection type Hygienic
Do not forget the washer.
Replace the washer with new spare part, if miss-
ing or damaged.
If the standard calibration data for axes 4, 5 or 6
should be updated with wrist optimization, run the
calibration routine Wrist Optimization.
© Copyright 2014 - 2021 ABB. All rights reserved.
5 Calibration
Continued
Note
xx1600001144
Protective plug for bushing:
3HAC059556-001.
Protective plug for bushing, Clean
Room
Protective plug for bushing, food
grade lubrication
Protective plug for bushing, Hygien-
ic
: 3HAC059557-001.
See
Calibrating with Wrist Optimiz-
ation method on page
834.
831