11
12
13
Product manual - IRB 1200
3HAC046983-001 Revision: S
Action
Pull out the cabling and then remove the axis-2
motor bracket from the cable package by remov-
ing the screws.
CAUTION
Do not loosen the cable clamp screw! There is a
risk of rearrangement of the cable layout which
would result in shortened lifetime of the cable
harness.
Disconnect the motor connectors.
•
R2.ME2
•
R2.MP2
Loosen the cable housing from the swing by re-
moving the screws. Leave it hanging on the cable
package.
© Copyright 2014 - 2021 ABB. All rights reserved.
4.3.1 Replacing the main cable package
Note
xx1300002433
xx1300002434
xx1300002435
Continues on next page
4 Repair
Continued