6.3 Updating revolution counters

6.3.1 Updating revolution counters on OmniCore robots

Introduction
This section describes how to do a rough calibration of each manipulator axis by
updating the revolution counter for each axis, using the FlexPendant.
Step 1 - Manually running the manipulator to the synchronization position
Use this procedure to manually run the manipulator to the synchronization position.
1
2
3
Correct calibration position of axis 4
When jogging the manipulator to synchronization position, it is extremely important
to make sure that axis 4 is positioned correctly. Axis 4 can be calibrated at the
wrong turn, resulting in an incorrect manipulator calibration.
Make sure axis 4 is positioned according to the cable harness status, not only
according to the synchronization marks. Use the following procedure to check and
correct the axis 4 position.
1
Product manual - IRB 1100
3HAC064992-001 Revision: L
6.3.1 Updating revolution counters on OmniCore robots
Action
Select axis-by-axis motion mode.
Jog the manipulator to align the synchron-
ization marks.
When all axes are positioned, update the
revolution counter.
Action
Remove the housing cover.
© Copyright 2019-2022 ABB. All rights reserved.
6 Calibration
Note
See
Synchronization marks and synchron-
ization position for axes on page
Step 2 - Updating the revolution counter
with the FlexPendant on page
Note
xx1800003011
Continues on next page
715.
720.
717