limit size <value>
Use the limit size command to trigger a packet capture (Pcap) file export after the combined size of all the
packet-capture's open captures exceeds the specified size. Use the no form of this command to return the
maximum open capture size limit to the default value.
Syntax Description
<value>
Default Values
By default, the maximum open capture size is set to 1M.
Command History
Release R10.1.0
Functional Notes
At least one capture limit, whether size or time, must be configured with a non-zero value before the
packet-capture can be enabled. Configure a size limit using this command, or a time limit using the
command
limit time <value> on page
size or time limits.
Usage Examples
The following example changes the maximum combined open capture size limit to 3M:
(config)#packet-capture 1CAPTURE standard
(config-packet-capture-1CAPTURE)#limit size 3M
60000CRG0-35E
Specifies the maximum combined size of the packet-capture's open
captures. This value can be expressed in bytes, kilobytes (k or K), or
megabytes (m or M). Valid range is 0 to 4095M. If the value is set to 0, the
size limit feature is disabled.
Command was introduced.
3265. ADTRAN recommends that you do not disable packet capture
Copyright © 2012 ADTRAN, Inc.