period <value>
Use the period command to specify the time between probe test attempts. Use the no form of this
command to return to the default setting.
Syntax Description
<value>
Default Values
By default, the period between probe tests is 60 seconds.
Command History
Release 13.1
Usage Examples
The following example specifies probe1 to initiate probe tests every 90 seconds:
(config)#probe probe1 icmp-echo
(config-probe-probe1)#period 90
60000CRG0-35E
Specifies the time (in seconds) between probe test attempts. Valid range is
1 to 65535 seconds.
Command was introduced.