data <pattern>
Use the data command to specify a hexadecimal pattern to repeat in the Internet Control Message Protocol
(ICMP) packet data section. Use the no form of this command to return to the default setting.
Syntax Description
<pattern>
Default Values
By default, the data pattern is a standard ping packet pattern of data values starting with 0x00,
incrementing by one for the length of the packet. Refer to
packet data patterns.
Command History
Release 13.1
Usage Examples
The following example specifies a data pattern of 0FF0 for probe1:
(config)#probe probe1 icmp-echo
(config-probe-probe1)#data 0FF0
60000CRG0-35E
Specifies a hexadecimal data pattern.
Command was introduced.
Copyright © 2012 ADTRAN, Inc.
Network Monitor Probe Command Set
ping on page 39
for more information on ping