ADTRAN AOS Version R10.1.0 Command Reference Manual page 2978

Adtran operating system (aos)
Table of Contents

Advertisement

Command Reference Guide
dampening-interval
Use the dampening-interval command to specify an amount of time to wait before allowing a new probe
status change to trigger a new action. Use the no form of this command to return to the default setting.
Variations of this command include:
dampening-interval <value>
dampening-interval fail<value>
dampening-interval pass <value>
Syntax Description
<value>
fail <value>
pass <value>
Default Values
By default, the interval is set to 1 seconds.
Command History
Release 13.1
Release 14.1
Usage Examples
The following example sets the dampening interval to 90 seconds for a fail-to-pass transition:
(config)#track track1
(config-track-track1)#dampening-interval pass 90
60000CRG0-35E
Specifies the time interval value in seconds. Valid range is 1 to 4294967295
seconds. If neither the fail or pass subcommand is specified, the value will
be used for both conditions.
Specifies the delay in seconds following pass-to-fail transitions before a
new action can be triggered.
Specifies the delay in seconds following fail-to-pass transitions before a
new action can be triggered.
Command was introduced.
Command was expanded to include the fail and pass criteria.
Copyright © 2012 ADTRAN, Inc.