ADTRAN AOS Version R10.1.0 Command Reference Manual page 2989

Adtran operating system (aos)
Table of Contents

Advertisement

Command Reference Guide
Tracking:
Currently, track LB is in a PASS state. Due to the AND Boolean logic for this test list, track LB is in a PASS
state because the test probe statements within the test list (probe LB and LB2) are also BOTH in a PASS
state.
Now, probe LB has been forced to fail for demonstration purposes in this example. Output from the show
track LB command shows track LB in a FAIL state.
(config-loop 1)#do show track LB
Current State: FAIL
Testing:
probe LB (FAIL)
AND probe LB2 (PASS)
Dampening Interval: 1 seconds
Time in current state: 0 days, 0 hours, 0 minutes, 10 seconds
Track State Changes: 3
Tracking:
Probe LB is now in a FAIL state. As a result, track LB is also in a FAIL state.
If the test list in this example had specified the OR Boolean logic (using the test list or
command), then track LB would have passed even though one of the test probes was in the
FAIL state.
60000CRG0-35E
(Admin: UP)
Copyright © 2012 ADTRAN, Inc.
Network Monitor Track Command Set