Command Reference Guide
dialtone timeout <value>
Use the dialtone timeout command to specify the dial tone detection timeout period (in milliseconds) for
dial tone detection.
Syntax Description
<value>
Default Values
By default, the dial tone detection timeout period is 2000 milliseconds for the United States, Puerto Rico,
and Canada and is 4000 milliseconds for all other supported countries.
Command History
Release A4.05
Usage Examples
The following example specifies that analog loop start trunk t01 will use a 3000 milliseconds dial tone
detection timeout period:
(config)#voice trunk t01 type analog supervision loop-start
(config-t01)#dialtone timeout 3000
60000CRG0-35E
Specifies the dial tone detection timeout period in milliseconds. Valid rage is
1500 to 60000 milliseconds.
Command was introduced.