Command Reference Guide
ccm interval
Use the ccm interval command to specify how frequently maintenance endpoints (MEPs) of this
association send continuity check messages (CCMs). Use the no form of this command to return to the
default value. Variations of this command include:
ccm interval 100ms
ccm interval 1s
ccm interval 10s
ccm interval 1m
ccm interval 10m
Syntax Description
100ms
1s
10s
1m
10m
Default Values
By default, the continuity check message (CCM) interval is set to 1 second.
Command History
Release 17.4
Functional Notes
For more information regarding Ethernet operations, administration, and maintenance (OAM) connectivity
fault management (CFM) and its operation on AOS products, refer to the Ethernet OAM CFM in AOS
configuration guide available online at
Usage Examples
The following example sets the CCM interval to 1 minute:
(config-ecfm-domain)#association association1
(config-ecfm-assoc)#ccm interval 1m
(config-ecfm-assoc)#
60000CRG0-35E
Specifies the interval as 100 milliseconds.
Specifies the interval as 1 second.
Specifies the interval as 10 seconds.
Specifies the interval as 1 minute.
Specifies the interval as 10 minutes.
Command was introduced.
https://supportforums.adtran.com
Copyright © 2012 ADTRAN, Inc.
Ethernet OAM CFM Command Set
(article number 3013).