1634
C
96: MPLS TE C
HAPTER
Example

mpls te timer auto-bandwidth

Syntax
View
Parameter
Description
Related command:
Example
C
ONFIGURATION
OMMANDS
n
The tie breaker configured in MPLS TE tunnel interface view has higher priority
over the one configured in MPLS view.
# Configure CSPF to route tunnels over paths with the least bandwidth usage
ratio.
<Sysname> system-view
[Sysname] mpls
[Sysname-mpls] mpls te tie-breaking least-fill
# Configure CSPF to route tunnel 0 over a path with the least bandwidth usage
ratio in MPLS TE interface view.
<Sysname> system-view
[Sysname] interface tunnel 0
[Sysname-Tunnel0] mpls te tie-breaking least-fill
mpls te timer auto-bandwidth [ seconds ]
undo mpls te timer auto-bandwidth
MPLS view
seconds: Interval for output rate sampling for tunnels configured with automatic
bandwidth adjustment, in the range 1 to 604800 seconds. If it is not configured,
the default of 300 seconds applies. You are recommended to use the default in
normal cases.
Use the
mpls te timer auto-bandwidth
bandwidth adjustment and set the interval for output rate sampling for tunnels
governed by automatic bandwidth adjustment.
Use the
undo mpls te timer auto-bandwidth
default.
By default, automatic bandwidth adjustment is disabled.
n
Support for this command varies by default.
To change the output rate sampling interval, use the undo mpls te timer
auto-bandwidth command to disable automatic bandwidth adjustment first
and then use the mpls te timer auto-bandwidth command to re-configure
it.
mpls te auto-bandwidth.
# Collect the output rates of MPLS TE tunnels automatically every 10 seconds or
600 seconds.
command to enable automatic
command to restore the