Mpls Te Timer Fast-Reroute; Mpls Te Timer Retry - H3C MSR 20-20 Command Reference Manual

Msr 20/30/50 series routers
Hide thumbs Also See for MSR 20-20:
Table of Contents

Advertisement

mpls te timer fast-reroute

Syntax
View
Parameter
Description
Example

mpls te timer retry

Syntax
View
Parameter
Description
<Sysname> system-view
[Sysname] mpls
[Sysname-mpls] mpls te timer auto-bandwidth 600
mpls te timer fast-reroute [ seconds]
undo mpls te timer fast-reroute
MPLS view
seconds: FRR polling timer setting for the point of local repair (PLR) to poll
available bypass tunnels for the best one. It ranges from 0 to 604800 seconds,
with 0 disabling the PLR to poll available bypass tunnels regularly for the best one.
The default is 300 seconds or 5 minutes.
Use the
mpls te timer fast-reroute
Use the
undo mpls te timer fast-reroute
The default FRR polling timer is 300 seconds.
n
This command is not supported when the signaling protocol is CR-LDP.
# Set the FRR polling timer to 120 seconds or 2 minutes.
<Sysname> system-view
[Sysname] mpls
[Sysname-mpls] mpls te timer fast-reroute 120
mpls te timer retry second
undo mpls te timer retry
Tunnel interface view
second: Interval for re-establishing the tunnel, in the range 1 to 4294967295
seconds.
Use the
mpls te timer retry
re-establishing the tunnel.
Use the
undo mpls te timer retry
The default interval for re-establishing a tunnel is 10 seconds.
command to set the FRR polling timer.
command to disable FRP polling.
command to configure the interval for
command to restore the default.