OAP manager timers
The OAP manager uses the following timers:
•
Clock synchronization timer—Regularly triggers the OAP manager to send clock and time
zone synchronization notifications to OAP clients. This mechanism keeps the clients' clocks
synchronized with the manager's clock.
•
Client monitoring timer—Regularly triggers the OAP manager to send client monitoring
packets to OAP clients.
Configuring the OAP manager
Enabling OAP
Step
1.
Enter system view.
2.
Enter interface view.
3.
Enable OAP.
Setting the clock synchronization timer
Step
1.
Enter system view.
2.
Set the clock synchronization
timer.
Setting the client monitoring timer
Step
1.
Enter system view.
2.
Set the client monitoring timer.
Managing OAP clients
You can restart or shut down an OAP client.
Restarting an OAP client
Step
1.
Enter system view.
Command
system-view
interface interface-type
interface-number
oap enable
Command
system-view
oap timer clock-sync minutes
Command
system-view
oap timer monitor seconds
Command
system-view
5
Remarks
N/A
N/A
By default, OAP is disabled on an
interface.
Remarks
N/A
By default, the clock
synchronization timer is set to 5
minutes.
Remarks
N/A
By default, the client monitoring
timer is set to 5 seconds.