display dar information
Syntax
View
Parameters
Description
Examples
undo dar protocol-statistic
Interface view
time: Time interval between statistics actions , in minute, in the range 1 to 30. By
default, it is 5 minutes.
Use the
dar protocol-statistic
function.
Use the
undo dar protocol-statistic
With DAR packet statistics function, users can timely monitor the packet number,
data stream volume, historical mean rate and historical maximum rate of
application protocol on each interface, thus to facilitate implementing
corresponding policies for the data streams.
By default, the function is disabled.
# Enable DAR packet statistics function on the interface Ethernet1/0, and set the
interval to 7 minutes.
<Sysname> system-view
[Sysname] interface Ethernet 1/0
[Sysname-Ethernet1/0] dar protocol-statistic flow-interval 7
display dar information
Any view
None
Use the
display dar information
DAR module.
# Display information about the DAR module.
<Sysname> display dar information
Max session count
Watched session count
Table 494 Description on the fields of the display dar information command
Field
Max session count
Watched session count
command to enable DAR packet statistics
command to disable the function.
command to display information about the
: 65536
: 1000
Description
The number of maximum sessions
The number of watched sessions
1865