Parameters
Description
Related commands:
Examples
isis timer holding-multiplier
Syntax
View
Parameters
seconds: Specifies the interval in seconds for sending Hello packets, ranging from
3 to 255.
level-1: Specifies the interval for sending Level-1 Hello packets.
level-2: Specifies the time interval for sending Level-2 Hello packets.
Use the
isis timer hello
packets.
Use the
undo isis timer hello
The default hello interval is 10 seconds.
n
If no level is specified, the hello interval applies to both Level-1 and Level-2 of
■
the current ISIS process. If a level is specified, the interval applies to the level.
This command is not supported on the loopback interface.
■
The broadcast link distinguishes between Level-1 and Level-2 packets, so you
■
need specify intervals for the two levels respectively. The point-to-point link
however does not distinguish, so you need not specify intervals respectively.
As the shorter the interval is, the more system resources will be occupied, you
■
should configure a proper interval as needed.
isis timer holding-multiplier.
# Configure Level-2 Hello packets to be sent every 20 seconds over the serial2/0
interface.
<Sysname> system-view
[Sysname] interface serial 2/0
[Sysname-Serial2/0] isis timer hello 20 level-2
isis timer holding-multiplier value [ level-1 | level-2 ]
undo isis timer holding-multiplier [ level-1 | level-2 ]
Interface view
value: Number of hello intervals, in the range of 3 to 1000.
level-1: Applies the number to the Level-1 IS-IS neighbor.
level-2: Applies the number to the Level-2 IS-IS neighbor.
n
If neither level-1 nor level-2 is specified in the command, the number applies to
■
the current level IS-IS process.
This command is not available in loopback interface view.
■
command to specify the interval for sending hello
command to restore the default.
1071