Display Controller Cpos E1 - H3C MSR 20-20 Command Reference Manual

Msr 20/30/50 series routers
Hide thumbs Also See for MSR 20-20:
Table of Contents

Advertisement

674
C
45: CPOS I
HAPTER

display controller cpos e1

Syntax
View
Parameter
Description
C
C
NTERFACE
ONFIGURATION
OMMANDS
Cpos4/0
CT1 3
Frame-format ESF, clock master, loopback not set
(Some information about T1 channels is omitted.)
Cpos4/0
CT1 83
Frame-format ESF, clock master, loopback not set
Cpos4/0
CT1 84
Frame-format ESF, clock master, loopback not set
Table 122 Description on the fields of the display controller cpos command
Field
Cpos4/0 current state
Description
Frame-format SDH, multiplex
AU-3, clock master, loopback
not set
Tx: J0: 0x01, J1: "NetEngine",
C2: 0x02
Rx: J0: 0x01, J1: "NetEngine",
C2: 0x02
Regenerator section:
Multiplex section:
Higher order path(VC-3-x):
Alarm:
Error:
Cpos4/0 CT1 1 is up
Frame-format ESF, clock master,
loopback not set
display controller cpos cpos-number e1 e1-number
Any view
cpos-number: CPOS interface number.
e1-number: Number of an E1 channel on a CPOS interface, in the range 1 to 63.
Use the
display controller cpos e1
configuration information of the specified E1 channel on the specified CPOS
interface.
is up
is up
is up
Description
Current physical state of the CPOS interface.
Interface description.
Physical layer information of the CPOS interface: the
framing format is set to SDH, AU-3 path is adopted, master
clock (internal clock signal) is used, and loopback is
disabled.
The sent overhead bytes.
The received overhead bytes.
Alarm and error statistics about the regeneration section.
Alarm and error statistics about the multiplex section.
Alarm and error statistics about the higher-order path. The
x in "VC-3-x" indicates the path number. When adopting
AU-3 path, one STM-1 has three higher-order paths
because it is multiplexed by three VC-3s. In the AU-4 path,
there is one higher-order path VC-4.
Alarm statistics.
Error statistics.
The current physical state of T1 channel 1 of the CPOS
interface 4/0.
Physical layer information of T1 channels: the framing
format is set to ESF, master clock (internal clock signal) is
used, and loopback is disabled.
command to display the physical layer