lldp fast-count
Syntax
lldp fast-count count
undo lldp fast-count
View
System view
Default level
2: System level
Parameters
count: Number of the LLDPDUs sent each time fast LLDPDU transmission is triggered. This argument
ranges from 1 to 10.
Description
Use the lldp fast-count command to set the number of the LLDPDUs sent each time fast LLDPDU
transmission is triggered.
Use the undo lldp fast-count command to restore the default.
By default, the number is 3.
Examples
# Configure to send four LLDPDUs each time fast LLDPDU transmission is triggered.
<Sysname> system-view
[Sysname] lldp fast-count 4
lldp hold-multiplier
Syntax
lldp hold-multiplier value
undo lldp hold-multiplier
View
System view
Default level
2: System level
Parameters
value: TTL multiplier, in the range 2 to 10.
Description
Use the lldp hold-multiplier command to set the TTL multiplier.
Use the undo lldp hold-multiplier command to restore the default.
1-18