Required tools and equipment
Equipment, etc.
Rotation tool
24 VDC power supply
Leak-down tester
Calibration Pendulum toolkit
Calibration tool box, Axis
Calibration
Standard toolkit
Deciding calibration routine
Decide which calibration routine to be used, based on the information in the table.
Depending on which routine is chosen, action might be required prior to beginning
the repair work of the robot, see the table.
1
Removing the axis-6 gearbox
Use these procedures to remove the axis-6 gearbox.
Preparations before removing the axis-6 gearbox
1
Product manual - IRB 6700
3HAC044266-001 Revision: N
Action
Decide which calibration routine to use for
calibrating the robot.
Reference calibration. External cable
packages (DressPack) and tools can
stay fitted on the robot.
Fine calibration. All external cable
packages (DressPack) and tools
must be removed from the robot.
If the robot is to be calibrated with refer-
ence calibration:
Find previous reference values for the axis
or create new reference values. These val-
ues are to be used after the repair proced-
ure is completed, for calibration of the ro-
bot.
If no previous reference values exist, and
no new reference values can be created,
then reference calibration is not possible.
If the robot is to be calibrated with fine
calibration:
Remove all external cable packages
(DressPack) and tools from the robot.
Action
Decide which calibration routine to use,
and take actions accordingly prior to begin-
ning the repair procedure.
© Copyright 2013 - 2018 ABB. All rights reserved.
4.8.6 Replacing the axis-6 gearbox
Article number
Note
3HAB7887-1
Used to rotate the motor pinion.
-
Used to release the motor brakes.
-
3HAC15716-1
Required if Calibration Pendulum is the
valid calibration method for the robot.
3HAC055412-001
Delivered as a set of calibration tools.
Required if Axis Calibration is the valid
calibration method for the robot.
-
Content is defined in section
toolkit on page
Note
Follow the instructions given in the refer-
ence calibration routine on the FlexPendant
to create reference values.
Creating new values requires possibility to
move the robot.
Read more about reference calibration for
Axis Calibration in
routine on page
Read more about reference calibration for
Pendulum Calibration in Operating manu-
al - Calibration Pendulum.
Note
4 Repair
Continued
Standard
829.
Reference calibration
799.
Continues on next page
777

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents