4 Repair
4.5.5 Replacing the lower arm
Continued
4
5
6
Continues on next page
396
Action
If used, push the DressPack tube a little
backwards.
Tip
Use tape and tie the axis-5 and axis-6
connectors and carrier into a bundle (if not
already done). This is done to facilitate the
removal and to avoid damaging the parts.
This will also make it easier to run the cable
harness through the inside of the upper
arm.
Remove the side cover on the arm tube.
© Copyright 2013 - 2018 ABB. All rights reserved.
Note
xx1400000720
xx1300000668
xx1300000557
Product manual - IRB 6700
3HAC044266-001 Revision: N