4 Repair
4.8.2 Replacing the axis-1 gearbox (IRB 6700 - 300/2.70, IRB 6700 - 245/3.00)
Continued
6
7
8
9
10
Continues on next page
656
Action
CAUTION
Whenever parting/mating motor and gear-
box, the gears may be damaged if excess-
ive force is used.
Lower the motor into position.
Make sure that the motor pinion is
properly mated to the gear in the
gearbox.
Make sure that the motor pinion
does not get damaged.
Make sure that the direction of the
cable gland exit is facing the correct
way.
Secure the motor with its attachment
screws and washers.
Use a bits extender to reach the screws.
Perform a leak-down test (if not already
done).
Disconnect the 24 VDC power supply.
© Copyright 2013 - 2018 ABB. All rights reserved.
Note
Lifting accessory (chain): 3HAC15556-1
Lifting accessory, motor: 3HAC14459-1.
xx1200001072
Bits extender: 3HAC12342-1
Tightening torque: 50 Nm.
Screws: M10x30 Steel 12.9 Gle
603+Geo500 (4 pcs)
xx1200001071
See
Performing a leak-down test on
page
198.