ABB IRB 6700 Series Product Manual page 183

Table of Contents

Advertisement

6
7
8
Product manual - IRB 6700
3HAC044266-001 Revision: N
Action
Inspect the oil level at the oil fill/level hole
(level plug).
Refit the oil plug.
DANGER
Make sure all safety requirements are met
when performing the first test run. These
are further detailed in the section
run may cause injury or damage on
page
26.
© Copyright 2013 - 2018 ABB. All rights reserved.
3.4.6 Changing oil, axis-5 gearbox
Note
xx1200000959
Required oil level is: 0 - 10 mm below the
oil plug hole.
More information is found in
oil level in axis-5 gearbox on page
Tightening torque: 24 Nm
First test
3 Maintenance
Continued
Inspecting the
131.
183

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents