Concluding procedure
1
2
Product manual - IRB 6700
3HAC044266-001 Revision: N
Action
Make sure that the cable harness is placed
in a way so it will not be damaged when
the wrist cover is fitted.
Inspect the gasket. Replace if damaged.
Foundry Plus and Foundry Prime:
Make sure that the gasket is undam-
aged on the cover. Replace if dam-
aged.
Put washers in the holes of the gas-
ket.
Use attachment screws made of
stainless steel to fit the wrist cover.
© Copyright 2013 - 2018 ABB. All rights reserved.
4.5.2 Replacing the wrist
Note
There are two versions of the heat protec-
tion plates.
Choose figure depending on which plate
is installed on the robot.
xx1500001672
xx1300000596
Cable layout in the wrist with Type A mo-
tors.
xx1400000383
A Protection plugs (2 on wrist cover
and 2 on cover axis-5 gearbox)
B Washers (10 pcs) in gasket holes