3HAC044266-001 Revision: N
Action
Inspect the oil level at the vent hole (level
plug).
Remove the oil dispenser.
Refit the protective cap on the nipple.
Refit the level plug.
DANGER
Make sure all safety requirements are met
when performing the first test run. These
are further detailed in the section
run may cause injury or damage on
page
26.
© Copyright 2013 - 2018 ABB. All rights reserved.
3.4.3 Changing oil, axis-2 gearbox
Note
xx1200000952
Required oil level is: 0-15 mm below the oil
plug hole.
More information is found in
oil level in axis-2 gearbox on page
Tightening torque: 24 Nm
First test
3 Maintenance
Continued
Inspecting the
124.