ABB IRB 6700 Series Product Manual page 175

Table of Contents

Advertisement

7
8
9
10
Product manual - IRB 6700
3HAC044266-001 Revision: N
Action
Inspect the oil level at the vent hole (level
plug).
Remove the oil dispenser.
Refit the protective cap on the nipple.
Refit the level plug.
DANGER
Make sure all safety requirements are met
when performing the first test run. These
are further detailed in the section
run may cause injury or damage on
page
26.
© Copyright 2013 - 2018 ABB. All rights reserved.
3.4.4 Changing oil, axis-3 gearbox
Note
xx1200000955
IRB 6700 - 235/2.65, IRB 6700 - 205/2.80,
IRB 6700 - 175/3.05, IRB 6700 - 150/3.20,
IRB 6700 - 200/2.60, IRB 6700 - 155/2.85
xx1500001645
IRB 6700 - 300/2.70, IRB 6700 - 245/3.00
Required oil level is: 0 - 20 mm below the
oil plug hole.
More information is found in
oil level in axis-3 gearbox on page
Tightening torque: 24 Nm
First test
3 Maintenance
Continued
Inspecting the
127.