ABB IRB 6700 Series Product Manual page 534

Table of Contents

Advertisement

4 Repair
4.7.3 Replacing the axis-3 motor
Continued
5
6
Removing the axis-3 motor
1
2
3
4
Continues on next page
534
Action
Remove the cable gland cover.
Make sure the gasket is not damaged.
Tip
Make a note in which direction the cable
gland hole is facing, if the motor will be re-
moved too. The motor shall be refitted in
the same position.
Use caution and pull out the motor cables.
Action
Before removing the motor, make sure that
the axis-3 gearbox is completely drained.
DANGER
When releasing the holding brakes of the
motor, the upper arm will be movable and
may fall down if not secured. Verify that
the upper arm is secured as previously
described, before continuing.
To release the brakes, connect the 24 VDC
power supply.
Connect to connector R2.MP3:
+ = pin 2
- = pin 5
Unscrew the attachment screws that hold
the motor.
Use a bits extender to reach the screws.
© Copyright 2013 - 2018 ABB. All rights reserved.
Note
xx1200001067
Note
Bits extender: 3HAC12342-1
xx1200001126
Product manual - IRB 6700
3HAC044266-001 Revision: N

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents