2 Installation and commissioning
2.7.2 Installing the motor cooling fan (option)
Continued
Required consumables
Consumable
Cable straps
Installing the cooling fan
Use these procedures to install the cooling fan.
Installing the fan
1
2
3
4
Continues on next page
104
Action
Move the robot to its synchronization position.
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the robot working
area.
Remove the metal sheet frame from the fan unit
assembly by loosening the six screws.
Loosen the two tightening screws so they don´t
damage the motor surface during installation.