7
8
Product manual - IRB 6700
3HAC044266-001 Revision: N
Action
Use caution and push the cable harness
into the wrist.
Tip
This step is best performed by two persons
working together:
Person 1: Put one hand inside the
side cover hole and take a hold of
the cable harness.
Person 2: Take a hold of the cable
harness from inside the wrist.
Together: Move the cable harness
past the axis-5 motor and into the
wrist.
Refit the metal clamp axis-4 inside the arm
tube.
Note
The screws are reached from outside the
upper arm!
© Copyright 2013 - 2018 ABB. All rights reserved.
4.4.2 Refitting the cable harness
Note
Person 1, working at the side hole:
xx1300000745
Person 2, working at the wrist:
xx1300000746
xx1700000340
xx1700000339
Continues on next page
4 Repair
Continued
271