4 Repair
4.4.1 Removing the cable harness
Continued
3
4
5
6
Continues on next page
240
Action
Make sure the o-ring is present.
Disconnect the motor cables.
Remove the cable gland cover.
Make sure the gasket is not damaged.
Tip
Make a note in which direction the cable
gland hole is facing, if the motor will be re-
moved too. The motor shall be refitted in
the same position.
Use caution and pull out the motor cables.
© Copyright 2013 - 2018 ABB. All rights reserved.
Note
xx1200001070
xx1200001066
xx1200001067