4 Repair
4.7.6 Replacing the axis-6 motor
Continued
Disconnecting the axis-6 motor cables
1
2
3
4
Continues on next page
574
Action
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
Unscrew the attachment screws and re-
move the motor cover.
Disconnect the motor cables.
Unscrew the attachment screws that hold
the cable bracket.