Troubleshooting

IMPORTANT:
The barcode stuck on the router chassis contains production and servicing information. Before you
return a faulty router for serving, provide the barcode information of the router to H3C Support.

MPU failures

RUN LED is off

Symptom
The RUN LED of the MPU is off. For more information about the RUN LED, see
Solution
To resolve the issue:
Verify that the MPU is installed in a right slot.
1.
An RPE-X1/RPE-X3/RPE-X5/RPE-X5E MPU must be installed in slot 0 or slot 1.
An RSE-X1 MPU must be installed in slot 1 or slot 2.
An MCP-X1/X2 must be installed in slot 1 or slot 2.
Verify that the router is powered on correctly. A green POWER LED indicates that the router is
2.
powered on correctly.
If the issue persists, contact H3C Support.
3.

RUN LED fast flashes

Symptom
Five minutes after the router is powered on or the MPU is inserted in the router, the RUN LED of the
MPU still fast flashes at 8 Hz.
Solution
To resolve the issue:
Verify that the terminal display is correct.
1.
Verify that the software image file properties are correct in the BootWare menu.
2.
If the issue persists, contact H3C Support.
3.

ALM LED is steady on or flashes

Symptom
The ALM LED of the MPU is steady on or flashes. A failure or exception has occurred.
For example, the ALM LED is on when the following message is displayed:
%Jun 25 14:38:45:444 2017 H3C DRVMSG/3/TempCritical:
CPU temperature critical in Slot 3, index is 1.
For more information about the ALM LED, see
"Appendix C
LEDs."
79
"Appendix C
LEDs."