2.
Verify that the router is powered on correctly. A green POWER LED indicates that the router is
powered on correctly.
3.
If the issue persists, contact H3C Support.
RUN LED fast flashes
Symptom
Five minutes after the router is powered on or the MPU is inserted in the router, the RUN LED of the
MPU still fast flashes at 8 Hz.
Solution
To resolve the issue:
1.
Verify that the terminal display is correct.
2.
Verify that the software image file properties are correct in the BootWare menu.
3.
If the issue persists, contact H3C Support.
ALM LED is steady on or flashes
Symptom
The ALM LED of the MPU is steady on or flashes. A failure or exception has occurred.
For example, the ALM LED is on when the following message is displayed:
%Jun 25 14:38:45:444 2017 H3C DRVMSG/3/TempCritical:
CPU temperature critical in Slot 3, index is 1.
For more information about the ALM LED, see H3C SR6604[6608] Routers Hardware Information
and Specifications.
Solution
To resolve the issue:
1.
Verify the output (such as the system temperature and PCB voltage alarms) on the serial
terminal and the software management tool.
2.
If the issue persists, contact H3C Support.
FIP module failures
RUN LED is off
Symptom
The RUN LED on the FIP module is off.
Solution
To resolve the issue:
1.
Verify that the router is powered on.
2.
Verify that the FIP module is installed in a right slot.
3.
Execute the
Slot3:
The Board is present, state is unknown
4.
If the issue persists, contact H3C Support.
display version
command to display system version information:
8-80