ABB CRB 15000 Product Manual page 545

Hide thumbs Also See for CRB 15000:
Table of Contents

Advertisement

Closing the housing top cover
1
2
3
Preparations before fitting the joint unit
1
Product manual - CRB 15000
3HAC077389-001 Revision: L
Action
Check the inner plate gasket.
Replace if damaged.
Refit the inner plate with the screws.
Refit the cover with the four screws.
Action
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit read the safety information in section
unit is sensitive to ESD on page
© Copyright 2021 - 2023 ABB. All rights reserved.
5.4.2 Replacing the housing
Note
Gasket: 3HAC075056-001
xx2000002095
Hex socket head cap screw: M3x8
12.9 Lafre 2C2B/FC6.9 (4 pcs).
Tightening torque: 1.4 Nm
xx2000002076
Hex socket head cap screw: M3x8
12.9 Lafre 2C2B/FC6.9 (4 pcs).
Tightening torque: 0.45 Nm
xx2000002075
Note
The
53.
5 Repair
Continued
Continues on next page
545

Advertisement

Table of Contents
loading

Table of Contents