ABB CRB 15000 Product Manual page 674

Hide thumbs Also See for CRB 15000:
Table of Contents

Advertisement

5 Repair
5.5.1 Replacing the base
Continued
Securing the base (-10/1.52 and -12/1.27)
1
Removing the swing (-10/1.52 and -12/1.27)
1
2
Continues on next page
674
Action
Lift the base to standing and secure it to the
foundation with the attachment screws and
washers.
Action
Valid for CRB 15000-10/1.52
Remove the swing transition.
Valid for CRB 15000-10/1.52
Remove the swing flange.
© Copyright 2021 - 2023 ABB. All rights reserved.
Note
Attachment screws: M10x35 8.8 (4
pcs).
Washers: 23/10.5/2.5 mm Steel (4 pcs).
Tightening torque: 32 Nm ±10%.
xxx
Note
xx2300000817
xx2300000818
Product manual - CRB 15000
3HAC077389-001 Revision: L

Advertisement

Table of Contents
loading

Table of Contents