5 Repair
5.5.1 Replacing the base
Continued
5
Loosening the base and removing the base cover
1
2
Disconnecting the axis-1 joint unit cabling
1
2
Continues on next page
676
Action
Lift away the swing.
CAUTION
The torque sensor (on the exposed PCBA) is
sensitive to mechanical damage. Handle the as-
sembly with care.
Action
Loosen the base from the foundation by removing
the attachment screws and washers.
Tilt the base on to its side and remove the bottom
cover by removing the attachment screws.
Action
Cut the cable ties.
Remove the functional and protective earth cables
by removing the screw.