5
Refitting the swing (-5/0.95)
Use these procedures to refit the swing.
Refitting the swing(-5/0.95)
1
2
3
Product manual - CRB 15000
3HAC077389-001 Revision: L
Action
Lift away the swing.
CAUTION
The torque sensor (on the exposed PCBA) is
sensitive to mechanical damage. Handle the as-
sembly with care.
Action
Clean the mounting surface with isopropanol.
Apply flange sealant to the corner of the base
mounting surface, as pointed out in the figure.
Separate the new swing parts by removing the
pre-assembling screws.
Refit the swing to the base unit, aligning the pin
with the pin hole.
CAUTION
The torque sensor (on the exposed PCBA) is
sensitive to mechanical damage. Handle the as-
sembly with care.
© Copyright 2021 - 2023 ABB. All rights reserved.
5 Repair
5.5.2 Replacing the swing
Continued
Note
Note
Cleaning agent: Isopropanol
Flange sealant: Loctite 574
xx2000001990
xx2000001989
Continues on next page
743