ABB CRB 15000 Product Manual page 748

Hide thumbs Also See for CRB 15000:
Table of Contents

Advertisement

5 Repair
5.5.2 Replacing the swing
Continued
4
5
Refitting the swing cover(-5/0.95)
1
Continues on next page
748
Action
Secure the cables for functional earth and
protective earth with a screw.
Secure the cabling with cable ties.
Action
Fit the o-ring to cover groove.
Replace if damaged.
© Copyright 2021 - 2023 ABB. All rights reserved.
Note
Hex socket head cap screw: M3x6 (1
pcs).
Tightening torque: 0.8 Nm.
xx2000001945
Cable ties (3 pcs)
xx2000001946
Note
O-ring: 3HAC061327-047 (for CRB
15000-5/0.95)
xx2000001962
Product manual - CRB 15000
3HAC077389-001 Revision: L