3HAC077389-001 Revision: L
Action
Cut the cable ties.
Remove the functional and protective earth cables
by removing the screw.
Snap loose and disconnect the connectors:
J2.DC+
J2.DC-
J2.CS
J2.CP
Disconnect the connectors from the drive board.
D2.X1 from X1
D2.DC+ from DC+
D2.DC- from ground
D2.X4 from X4
D2.X2 from X2
D2.X5 from X5
CAUTION
Use tweezers to unlock connectors and pull them
off.
© Copyright 2021 - 2023 ABB. All rights reserved.
5 Repair
5.5.1 Replacing the base
Continued
Note
xx2000001946
xx2000001945
xx2000001944
xx2000002013
Continues on next page