5 Repair
5.3.6 Replacing the axis-5 cabling
Continued
Removing the tubular cover
1
2
Removing the axis-4 cover
1
2
Continues on next page
420
Action
Valid for CRB 15000-5/0.95
Remove the cover by removing the six screws.
Dispose the screws. New screws must be used
when refitting the cover.
New screws are included in the spare part delivery
of the joint unit.
Valid for CRB 15000-10/1.52 and CRB 15000-
12/1.27
Remove the covers by removing the screws.
Action
Remove the cover screws.
CAUTION
Valid for CRB 15000-5/0.95
There is cabling connected between the cover
and the joint unit drive board.
Open the cover with care to avoid damage to the
cabling or the connector(s).
Do not leave the cover in location without being
secured with the attachment screws.
© Copyright 2021 - 2023 ABB. All rights reserved.
Note
xx2000002123
xx2300000841
Note
xx2000002083
Product manual - CRB 15000
3HAC077389-001 Revision: L