Action
Valid for CRB 15000-5/0.95
Clean the mounting surface with isopropanol.
Apply flange sealant to the corner of the lower
arm mounting surface, as pointed out in the figure.
Lift the upper arm into mounting position while
inserting the cabling into the lower arm.
Slide the upper arm into place on the guide pins.
Secure the upper arm to the lower arm with all
attachment screws but two.
Pre-tighten the screws crosswise firstly.
Remove the guide pins and fasten the remaining
two screws.
Torque tighten all screws crosswise.
© Copyright 2021 - 2023 ABB. All rights reserved.
5 Repair
5.4.2 Replacing the housing
Continued
Note
Cleaning agent: Isopropanol
Flange sealant: Loctite 574
xx2000001973
xx2000001970
Hex socket head cap flange screw:
M4x25 12.9 Lafre
2C2B/FC6.9+PrO-COat111 (16 pcs)
xx2000001969
Hex socket head cap flange screw:
M4x25 12.9 Lafre
2C2B/FC6.9+PrO-COat111 (16 pcs)
xx2000001967
Tightening torque: 4.6 Nm