5 Repair
5.6.7 Replacing the axis-5 joint unit and the axis-5 to axis-6 transition cabling
Continued
3
4
Removing the axis-5 joint unit
1
2
Continues on next page
996
Action
Snap loose and disconnect the connectors:
J5/6.DC+
J5/6.DC-
J5/6.CS
J5/6.CP
Disconnect the connectors from the drive board.
D4/5.X1
D5.DC+
D5.DC-
D4/5.X4
D5.X2
D4/5.X5
CAUTION
Use tweezers to unlock connectors and pull them
off.
Action
Fit the lifting aid to the joint unit, on the torque
sensor side.
CAUTION
The connectors and the joint unit cables are
sensitive to mechanical damage. Handle the as-
sembly with care.
Remove two attachment screws.
Dispose the screws.
New screws are included in the spare part delivery
of the joint unit.
© Copyright 2021 - 2023 ABB. All rights reserved.
Note
xx2000002137
Tweezers
xx2000002138
Note
Lifting aid: 3HAC077789-001
Screws: M3x12 (4 pcs)
xx2000002139
xx2000002140
Product manual - CRB 15000
3HAC077389-001 Revision: L