5 Repair
5.6.7 Replacing the axis-5 joint unit and the axis-5 to axis-6 transition cabling
Continued
3
4
5
6
Continues on next page
986
Action
Valid for CRB 15000-10/1.52 and CRB 15000-
12/1.27
Remove the cable brackets.
Remove the functional and protective earth cables
by removing the screw.
Snap loose and disconnect the connectors:
J4/5.DC+
J4/5.DC-
J4/5.CS
J4/5.CP
Disconnect the connectors that belongs to the
axis-5 cabling, from the axis-4 drive board:
D3/4.X2
D3/4.DC-
D3/4.DC+
Use tweezers, if needed.
© Copyright 2021 - 2023 ABB. All rights reserved.
Note
xx2300000843
xx2000002087
xx2000002089
Tweezers