5.6.3 Replacing the axis-2 joint unit (CRB 15000-5/0.95)
Action
Insert the cabling through the cable support and
fit the support to the drive board with the attach-
ment screws.
Keep the cabling loose, making sure not to twist
or strain it.
Use the cable tie to pre-fix the cable by hand.
© Copyright 2021 - 2023 ABB. All rights reserved.
5 Repair
Continued
Note
xx2000002056
Hex socket head cap screw: M3x30
12.9 Lafre 2C2B/FC6.9 (2 pcs)
Tightening torque: 0.45 Nm.
xx2000002055
xx2100000507