5 Repair
5.6.1 Replacing the axis-1 joint unit (CRB 15000-5/0.95)
Continued
4
Removing the axis-1 joint unit (-5/0.95)
1
2
Continues on next page
782
Action
Disconnect the connectors from the drive board.
•
D1.X1 from X1
•
D1.DC+ from DC+
•
D1.DC- from ground
•
D1.X4 from X4
•
D1.X2 from X2
•
D1.X5 from X5
•
DR.X8 from X8
CAUTION
Use tweezers to unlock connectors and pull them
off.
Action
Fit the lifting aid to the joint unit.
CAUTION
The connectors and the joint unit cables are
sensitive to mechanical damage. Handle the as-
sembly with care.
Remove two attachment screws.
Dispose the screws.
New screws are included in the spare part delivery
of the joint unit.
© Copyright 2021 - 2023 ABB. All rights reserved.
Note
xx2000002009
Note
Lifting aid: 3HAC077788-001
Screws: M4x35 (4 pcs)
xx2000001994
xx2100000296
Product manual - CRB 15000
3HAC077389-001 Revision: L